NEW STEP BY STEP MAP FOR DP50RB

New Step by Step Map For Dp50rb

New Step by Step Map For Dp50rb

Blog Article

1.two.two Warning Labels Warning Labels Indicating Be sure to carefully read through this guide before use unit. The next labels undoubtedly are a. Never area the machine with a sloped surface area. Or else the available in the event the procedure system may slide, causing own injuries or the product operates Using the cellular malfunction.

.. Webpage 161 The indicator around the printer Faults arise when the adapter turns orange, and the printing printer adapter runs. Disconnect and join the fails. electric power adapter, energy on the printer adapter once again, and validate if the printing is standard after 1 minute. Web site 163: Electrical Safety Inspection

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Permits utilization of various scanned angles to type one impression, leading to enhanced distinction resolution and improved visualization

Page a hundred forty five Cleanse control panel Tools: dry tender cloth, moderate soapy water  Method:  Use dry tender cloth to scrub the surface area of the method. When the procedure is soiled, moisten the soft cloth with delicate soapy h2o and wipe off any stains. Use dry gentle cloth to eliminate any humidity and allow all challenging surfaces to totally air-dry. Web page 146: Cleanse The Peripherals

three. Click on the higher icon during the monitor (prompts “Update” if you place the cursor on it), the update stage is performed, if fails, remember to send to R&D Heart. Figure 6-one Principal Monitor Servicing Screen 4. Just after update is thriving, restart the machine following energy off to help make the data powerful. HDD Partition ... Page 91 structured report relevant details file and DICOM viewing application Report report template obd.bin OBD details file version.txt Variation file Comment Remark file AnatomyImage Anatomical images Measurement Measurement library Doppler application and relevant boot configuration most important file and plug-ins, remote desktop server Multilanguage string file exe videoplay.

General performance Test five.five.1 Exam Method Resolution Detection depth Geometric Posture Precision Blackout location take a look at History the exam visuals five.five.2 Examination Content The image utilized here is just for reference, stick to the graphic effect in the actual NOTE: situation. Needs: Screen: set the distinction and brightness within the scientific application benefit (or maybe the default standing) Operation environment: dim area, simulating the clinical software natural environment. Site 76 In condition which the transverse resolution testing targets are horizontally exhibited, file the minimal length of two targets that may be Evidently identified. Repeat the Procedure previously mentioned for the transverse resolution screening targets at other depths. As shown in figure down below. Axial resolution ... Web site 77 When using the convex probe, continue to keep the transverse resolution testing targets to NOTE: be shown close to the midline. When using a linear probe with steer purpose, don't turn on the steer purpose when carry out the transverse resolution take a look at. Zoom during the region in which the targets Positioned if necessary. The diameter in the focus on place at a particular depth is equal to your transverse resolution at the depth. Webpage 78 5.

By continuing your check out on our Web-site, you're consenting to our use of cookies. Nonetheless, you may improve your cookie configurations at any time.  Cookie desire Acknowledge and Commence

Cookies are very important to the appropriate functioning of a web site. To help your knowledge, we use cookies to recall log-in details and supply protected log-in, obtain studies to improve site performance, and produce articles tailor-made for your interests.

Assist 4D probe; acknowledge the probe by way of the ID code; swap the 4D push sign by means of the  electrical relay to generate the 4D probe operate Typically. four.two.2 Main board The primary board could be divided into two sections: front-conclude of the primary board and back again-finish of the leading board.

Return to the technique preset interface. The choice standing alterations into Uninstalled. The uninstalling purpose is special to interior buyers.

This handbook may referring to information shielded by copyright or patents and would not convey any license under the patent rights Dp50rb login or copyright of Mindray, or of Other people. Web page nine: Statement

probe. The graphic abnormality can be attributable to Change the probe, or perhaps the swivel in the 4D probe or maybe the 4D generate swap the 4D drive board board.

Written content Process Look at the battery periodically : a) Look at if battery is usually charged Typically when electrical power-on: That the current potential is one hundred% or potential boosts soon after a brief time suggests that the battery is often billed Generally.

Report this page